제품명

HAAS-3000/2000 적분구 시스템

The world's leading high-precision rapid spectroradiometer

적분구 크기
0.3m, 0.5m, 1m, 1.5m, 1.75m, 2m, 2.5m, 3m 적분구
목록보기
Typical Application Scenarios
HAAS-3000/2000 High Accuracy Array Spectroradiometer delivers various photometric, colorimetric and radiometric parameters as required by CIE standards. Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
Everfine
Main Characteristics
1.Innumerable Awards & Honors
"National High-Tech Program (863 program) Research Achievement", "US Patent Granted (No.: US 7,978,324 B2)", "China Excellent Patent Award", "Independent Innovation Product", "National Key& New Product",etc.
Everfine
2.Remarkable Stray Light Control
Thanks to the highly matched high-precision grating and science-grade TC-cooling detector, and using BWCT technology with modified NIST stray light correction technology,so the stray light reaches the extremely great level of 5.0E-05.
Everfine
3. Wide Linear Dynamic Range
The wide linearity dynamic range of the HAAS-3000/2000 is further extended by rigorous optical matching and EVERFINE SBCT patented technology.
4. Fast Measurement Speed
HAAS-2000/3000 measurement functions including but not limited to constant-state optical characteristics.The transient optical characteristics can be easily captured through the synchronous trigger function even the transient pulse is less than microseconds.
Everfine
5. High Accuracy
The instrument is specially designed for high-accuracy applications. Through the improved design of TE-cooling array CCD and accurate optical grating, along with the precise optical system and electronic circuit, the instrument delivers high resolution, high sensitivity and high SNR.
6. High Repeatability & Stability
Extremely high measurement repeatability and stability are achieved by TC-cooling technology that controls the influence of ambient temperature to the level of ±0.05 ° C, and no mechanical scanning mechanism.
7. High Sensitivity
The EVERFINE designed high-precision grating and HAMAMATSU TE-cooling array detector make the sensitivity of the instrument great to 0.01mcd, which is in the world's leading level.
Everfine
Technical Specifications